The Delta P pulse valve controller panel is equipped with a digital display that can sequentially display the working sequence of the pulse valve. According to the cleaning requirements, the pulse width, pulse interval, cycle, output digit can be adjusted to control the opening and closing of the solenoid valve, and the dust collector can be cleaned at a scheduled time. At the same time, it can be changed to differential pressure dust cleaning. Simply connect the air pipe to the controller, and intelligent control can be achieved under the combination control of seven differential pressure parameters.
For the convenience of users to freely combine the number of pulse valves controlled, an extended output module is adopted, and the number of controls can be increased or decreased at will.
Product parameter:
| Parameter name | Set range | Factory value |
| Pulse width | 0.02~2.55s | 0.08s |
| Pulse interval | 1~255s | 10s |
| Cycle time | 0~255min | 0min |
| Output digit numbers | 1~40 channel | 10/20/30/40 |
| Trigger method | 1:Timing 2:Delta P 3:Mixed 4: External | 1:Timing |
| DP cleaning start-up value | 0.04Kpa~4.00Kpa | 2.5Kpa |
| DP cleaning return difference value | 0~3.90Kpa | 1.00Kpa |
| Trigger value of high differential pressure alarm | 0.04~4.00Kpa | 3.00Kpa |
| Differential pressure high alarm return value | 0~3.39Kpa | 0.10Kpa |
| Trigger value of low pressure differential alarm | 0.01~3.90Kpa | 0.50Kpa |
| Low pressure differential alarm return value | 0~3.98Kpa | 0.01Kpa |
| Upper limit of mixed injection timing | 1~360min | 255min |
| Zero point calibration of differential pressure measurement value | / | 0Kpa |
| Power on delay | 1~99s | 5s |
| Digital tube brightness | 1~7 | 5 |