1.Product introduction:
Embedded type pulse valve, also known as the blowing pipeline valve of the pulse bag filter cleaning system. Controlled by an electronic control instrument, pulsating “impulse” blowing is carried out to clean the dust. Used in working with XC-PGQ-Y blowpipe connectors, it is reliable to use and easy to install and maintain.
2.Working principle:
The pulse valve consists of an solenoid post, a diaphragm, and a valve body. The area of the rear chamber of the diaphragm is larger than that of the front chamber, and the pressure force is large, causing the diaphragm to be in the closed position.
The pulse controller inputs an electrical signal, causing the solenoid post to engage the moving column, open the unloading hole, and quickly discharge the pressure gas in the rear chamber of the diaphragm. The pressure gas in the front chamber of the diaphragm lifts the diaphragm, opens the channel, and the pulse valve blows.
The electric pulse signal disappears, and the spring of the solenoid post immediately resets the moving column to close the unloading hole. The gas pressure and spring force in the rear chamber of the diaphragm close the channel, and the valve stops blowing.
The damping hole on the diaphragm plays a role in damping the airflow when the pilot head moves the column to lift the gas pressure for unloading. When the unloading hole is closed, the pressure gas quickly fills the rear chamber, causing the diaphragm to close the channel and stop blowing.
Certificates: CE, CCC, ROHS, IP65;
3.Structural characteristics:
The DCF-Y pulse valve developed by Xiechang is a in-line structure (also known as an embedded structure), which is directly installed on the distribution box. It has better direct injection, low resistance, small pressure loss, and expands the range of gas source pressure use, making it suitable for situations with low gas source pressure.

4. Technical standard:
| Technical category | Relevant parameter |
| Working pressure | 0.2~0.6MPa |
| Woring medium | Clean air |
| Working voltage | DC24V(AC220V/50Hz) |
| Current | 1.25A(0.5A) |
| Protection level | IP65 |
| Usage environment | 1. Room temperature diaphragm -10 ℃~55 ℃
2. The relative humidity of the air shall not exceed 85% |
| Diphragm service life | About 1 million times blowing |
5. Product parameters:
| Y Model No. | Y Valve size | Blowpie diameter | Diaphragm | |
| British (inch) | Metric (mm) | |||
| DCF-Y-25 | 1″ | 1″ | 25 | Single diaphragm |
| DCF-Y-40S | 1 1/2″ | 1 1/2″ | 40 | Double diaphragm |
| DCF-Y-50S | 2″ | 2″ | 50 | Double diaphragm |
| DCF-Y-62S | 2 1/2″ | 2 1/2″ | 62 | Double diaphragm |
| DCF-Y-76S | 3″ | 3″ | 76 | Double diaphragm |
| DCF-Y-102S.B | 3 1/2″ | 3 1/2″ | 102 | Double diaphragm |
| DCF-Y-102S | 4″ | 4″ | 102 | Double diaphragm |