Working principle:
The pulse valve consists of an solenoid post, a diaphragm, and a valve body. The area of the rear chamber of the diaphragm is larger than that of the front chamber, and the pressure force is large, causing the diaphragm to be in the closed position.
The pulse controller inputs an electrical signal, causing the solenoid post to engage the moving column, open the unloading hole, and quickly discharge the pressure gas in the rear chamber of the diaphragm. The pressure gas in the front chamber of the diaphragm lifts the diaphragm, opens the channel, and the pulse valve blows.
The electric pulse signal disappears, and the spring of the solenoid post immediately resets the moving column to close the unloading hole. The gas pressure and spring force in the rear chamber of the diaphragm close the channel, and the valve stops blowing.
The damping hole on the diaphragm plays a role in damping the airflow when the pilot head moves the column to lift the gas pressure for unloading. When the unloading hole is closed, the pressure gas quickly fills the rear chamber, causing the diaphragm to close the channel and stop blowing.
Certificates: CE, CCC, ROHS, IP65;
Model specifications:
| Type | Model No. | Size | Metric(mm) |
| Threaded explosion-proof valve
DCF-F-Z model DCF-F-2L-B model |
DCF-F-2L-B | 3/4″ | 20 |
| DCF-F-Z-20 | 3/4″ | 20 | |
| DCF-F-Z-25 | 1″ | 25 | |
| DCF-F-Z-40S | 1 1/2″ | 40 | |
| DCF-F-Z-50S | 2″ | 50 | |
| DCF-F-Z-62S | 2 1/2″ | 62 | |
| DCF-F-Z-76S | 3″ | 76 | |
| Coupling explosion-proof valve
DCF-F-ZM model |
DCF-F-ZM-20 | 3/4″ | 20 |
| DCF-F-ZM-25 | 1″ | 25 | |
| DCF-F-ZM-40S | 1 1/2″ | 40 | |
| Embedded explosion-proof valve
DCF-F-Y model |
DCF-F-Y-25 | 1″ | 25 |
| DCF-F-Y-40S | 1 1/2″ | 40 | |
| DCF-F-Y-50S | 2″ | 50 | |
| DCF-F-Y-62S | 2 1/2″ | 62 | |
| DCF-F-Y-76S | 3″ | 76 | |
| DCF-F-Y-102S | 4″ | 102 |
Working condition:
- Altitude not exceeding 1000m
- Environmental temperature -20 ℃~+40 ℃
- The relative humidity of the surrounding environment shall not exceed 95% (+25 ℃)
- In Zone 1 or Zone 2 environments with explosive mixtures formed by the mixing of Class II • t1~t4 combustible gases, vapors, and air, or in Zone 20 environments with combustible dust type a
- In a gas or steam environment without damaging insulation
- In areas without significant shaking and shock vibrations
- Places that can prevent dripping
I. Vacuum treatment for solenoid coil to eliminate harmful impurities, it makes the pilot work more sensative and reliable;
II. Orifice and unloading port match with the pulse valve, fast opening and closing, so it increases the blowing volume per unit time;
III. Membrane: Effective bonding and Sufficient tensile strength, Reliable sealing, Great anti-corrosion and anti-aging properties, we are the only company in China to use high-performance diaphragm so that it ensures long-term operation reliability. The company which provide us diaphragms also supply diaphragm to GOYEN and ASCO valve, it’s the same supplier. We guarantee at least 1millon times of service life(5 years).
IV. We are using high-quality pressure spring to guarantee at least 1millon times of service life.